Clovis Industrial Park

aerial photo of site

Location: Subdivision of the East half Section 24, T2N R35E (Enterprise Drive at County Road ‘K’), Clovis, NM

Owner: Clovis Industrial Development Corporation

Size: 236 acres

Zoning: Industrial park in development; Agricultural before city acquisition

Asking Price: $25,000 per acre

Clovis Industrial Park Brochure (PDF)

Highway Access: 1.7 miles to US 60. 61 miles to I-40 point. 105 miles to I-27 to I-40 at Amarillo, TX

Air Access: 11 miles to Clovis Municipal Airport (12 weekly flights to DFW)

Rail Access: BNSF Freight Classification Yard is approximately one mile from site. This is a major operations hub for BNSF’s Southern Transcom Line. Spur tracks on site.

Electric Power: Xcel Energy. Transmission line adjacent to SE corner of site; up to 120 MW can be served via 115kV delivery point without upgrades upon construction of substation tap or near the east border of the site.

Natural Gas: New Mexico Gas Company. Depends on lot selected but maximum is .5 mile. 4 inch line operates at 50 PSI. Second Feed being brought in from another direction but not looped up yet.

Water: EPCOR Water. 12" industrial water lines are installed in place to sites within Park. Potable water available for domestic or sanitation use primarily. Reuse available 5 MGD. 70 PSI on site, 92 PSI at closest hydrant.

Sewer: City of Clovis. Sewer is installed at Park. Maximum distance .25 mile depending on lot selected. 18 inch, 1.1 MGD.

Storm Water: City of Clovis. Future site owner responsible for maintaining runoff difference between pre- and post constuction

Telecom/Fiber: Two carriers, one with fiber within Park (Century), the other (Plateau) on Curry Road K (east border of Park).

Available Site Due Diligence Documentation

Title Commitment: Yes
Aerial Site Views and Maps: Yes
Park Master Plan: Yes
Utility Service Maps: Yes
Site Dimensions and Configuration: Yes
Wetlands Map: Yes
Phase 1 Environmental Assessment: Yes
Archeological and Historic Use Assessments: Yes
Park Covenants and Restrictions: Yes
Transportation Access Maps: Yes
Geotechnical Study/ Soil Survey: Yes
FEMA Flood Plain Designation with Map: Yes
Air Attainment Status: Yes
Endangered Species Assessment: Not required

Available General Community Information

Community Profile and Demographics: Yes
State and Local Incentives Overview: Yes
Letters of Support: Yes
Business and Industrial Support Services and Amenitites Profile: Yes

Economic Development Contact

Chase Gentry, Executive Director

Clovis Industrial Development Corporation
105 E. Grand Ave.
Clovis, NM 88101

Xcel Energy Contact

Stephaniey Dybsky, Manager, Corporate Economic Development

Xcel Energy
1800 Larimer Street
Denver, CO 80202